Description

There used to be a pre and post level in the blue graph for both the dynamics and the gate. In the new version it seems like it only has the pre-level and doesn't show post reduction level?
This was one of the most stand out features of the old version of the app.

Mixer Model: M32r/X32 Rack

App Version: 1.0.01 (268)

Event Timeline

alok added a subscriber: alok.Mar 18 2019, 12:42 AM
david added a subscriber: david.Mar 18 2019, 7:21 AM

I removed the post level to make the UI more clear. Also the post level wasn't that accurate since it didn't include the makeup gain of the compressor.
If you really want/need this feature back again I can add it as an option

david closed this task as Wontfix.Wed, Apr 17, 2:03 PM
david claimed this task.

For now this feautre won't be implemented again. The reasons are:

  • Post level is not supported by many mixers - using the preamp level is too inaccurate to be usable
  • Showing less lines makes the graph more readable