IDCA problems on monitor sends.
Closed, ResolvedPublic

Description

Hi, I’m having problems with IDCA’s on monitor sends in mixing station pro.

I have eight channels of drums on one IDCA feeding a stereo IEM mix on the X32 core.

Everything is set up ok but when I move the main IDCA fader I’m losing the relative positions on the individual drum sends. The more I move the fader the worse the problem gets.

I’m on the latest app version (Android) but this problem has been ongoing for a while now.

Any ideas?

Thanks,

Paul.

Mixer Model: X32 and X32 core

App Version: Mixing Station Pro V1.0.01

Event Timeline

david triaged this task as Low priority.Apr 15 2019, 3:03 PM
david added a subscriber: david.

Need more details for that.
As soon as a send in the IDCA gets changed the values are recalculated. The IDCA moves all faders relative to eachother in dB so they should stay in the same levels all the time.

david closed this task as Resolved.Jun 1 2019, 11:56 AM